Product Description
WE-170802GY-1000 12-2 PE-45 Twisted Blue-Red Grey Jacket Decoder Cable 1,000FT - Hunter, Baseline & Underhill
|
|
P7354D - Rev 1 |
|
HUNTER JACKETED |
![]() |
| 1.0 | SCOPE | ||
| 1.1 | This specification covers jacketed cables containing two UL listed Sprinkler Systems Wires, single conductor, suitable for direct burial, for operation up to 600 volts, and temperatures up to 60ºC. | ||
| PAIGE PART NO. | SIZE | JACKET COLOR | OUTSIDE DIAMETER | PUT-UPS | SHIPPING WEIGHT | ||||
|---|---|---|---|---|---|---|---|---|---|
| AWG | mm2 | Inches | mm | Feet | meters | Lbs/2500' | Kg/762m | ||
| 170801BU | 14 | 2,08 | Blue | .378 ± .020 | 9,6 ± 0,5 | 2500 | 762 | 163 | 74 |
| 170801GY | Gray | ||||||||
| 170801PR | Purple | ||||||||
| 170801YL | Yellow | ||||||||
| 170801OG | Orange | ||||||||
| 170801TN | Tan | ||||||||
| 170801RD | Red | ||||||||
| 170802BU | 12 | 3,32 | Blue | 0.62 ± .020 | 15,8 ± 0,5 | 200 | 91 | ||
| 170802GY | Gray | ||||||||
| 170802PR | Purple | ||||||||
| 170802YL | Yellow | ||||||||
| 170802OG | Orange | ||||||||
| 170802TN | Tan | ||||||||
| 170802RD | Red | ||||||||
Product Description
|
2.0 |
CONSTRUCTION: | ||
| 2.1 | Inner Conductors: | ||
| Soft drawn bare copper meeting the requirements of ASTM specification B-3 or B-8. Insulation shall be low density high molecular weight polyethylene and a thickness of 0.045", per Paige Electric specification P7079D. The two conductors (blue and red) shall be twisted with a minimum lay of 4". | |||
| 2.2 | Overall jacket: | ||
| High density polyethylene with a thickness of 0.035". Available with different color jackets. The jacket shall be sufficiently round, and loose, to facilitate its removal when being stripped. | |||
| 2.3 | Surface Print: | ||
| 2.31 | Inner Conductors – "Paige Electric P7079D 14 AWG PE UL Number 600V Sprinkler System Wire Direct Burial" | ||
| 2.32 | Outer Jacket – "Paige Electric, P7354D, 14 AWG PE UL Number 600V Sprinkler System Wire Direct Burial Only for Hunter Decoder Systems RoHS" | ||
| 3.0 | TEMPERATURE RATING | |
| 3.1 | Color Code: | |
| -55ºC to +60ºC | ||
| 4.0 | SPLICING RECOMMENDATIONS | |
| 4.1 | Underground splices shall be made in accordance with National Electrical Code® Articles 300.5 (Underground Installations) and 110.14 (Electrical Connections) using 3M DBY-6 or DBR-6 connectors, which are UL listed under "UL 486D-Direct Burial", for wet or damp locations, 600 volts. Connectors that are not listed at all, or listed under UL Standard UL 486C as "Compression Connectors", shall not be allowed. | |
| 5.0 | PUP-UPS | |
| 5.1 | 2500' (762mm) and some odd lengths. | |
Replacement for
Paige Electric 170802GY