| Table Losses same for all controlled OD | |||||||||||||
| SDR 32.5 thermoplastic pipe. | |||||||||||||
| PRESSURE LOSS | |||||||||||||
| C = 150 | 125 psi PR SDR 32.5 PVC PIPE | ||||||||||||
| Pipe Sizes: Nominal Losses per 100 ft: lb/in2 | |||||||||||||
| gpm | 2 in(1) | 2-1/2 in(1) | 3 in | 4 in | 6 in | gpm | 2-1/2 in | 3 in | 4 in | 6 in | 8 in | 10 in | 12 in |
| 5 | 0.018 | 0.007 | 0.003 | 0.001 | 160 | 4.22 | 1.61 | 0.471 | 0.071 | 0.020 | 0.007 | 0.003 | |
| 10 | .064 | .025 | .010 | .003 | 170 | 4.72 | 1.80 | .526 | .080 | .022 | .008 | .003 | |
| 15 | .135 | .053 | .020 | .006 | .001 | 180 | 5.24 | 2.00 | .585 | .089 | .025 | .008 | .004 |
| 20 | .230 | .090 | .034 | .010 | .002 | 190 | 2.22 | .647 | .098 | .027 | .009 | .004 | |
| 25 | .348 | .136 | .052 | .015 | .002 | 200 | 2.44 | .711 | .108 | .030 | .010 | .004 | |
| 30 | .487 | .190 | .073 | .021 | .003 | 210 | 2.67 | .778 | .118 | .033 | .011 | .005 | |
| 35 | .648 | .253 | .097 | .028 | .004 | 220 | 2.91 | .848 | .129 | .036 | .012 | .005 | |
| 40 | .829 | .324 | .124 | .036 | .005 | 230 | 3.16 | .921 | .140 | .039 | .013 | .006 | |
| 42 | .907 | .355 | .136 | .040 | .006 | 240 | 3.41 | 0.996 | .151 | .042 | .014 | .006 | |
| 44 | 0.989 | .387 | .148 | .043 | .007 | 250 | 3.68 | 1.07 | 0.163 | 0.045 | 0.015 | 0.007 | |
| 46 | 1.07 | .420 | .161 | .047 | .007 | 260 | 3.96 | 1.16 | .175 | .049 | .017 | .007 | |
| 48 | 1.16 | .454 | .174 | .051 | .008 | 270 | 1.24 | .188 | .052 | .018 | .008 | ||
| 50 | 1.25 | 0.490 | 0.187 | 0.055 | 0.008 | 280 | 1.33 | .201 | .056 | .019 | .008 | ||
| 52 | 1.35 | .527 | .202 | .059 | .009 | 290 | 1.41 | .215 | .059 | .020 | .009 | ||
| 54 | 1.44 | .565 | .216 | .063 | .010 | 300 | 1.51 | .229 | .063 | .022 | .009 | ||
| 56 | 1.55 | .604 | .231 | .067 | .010 | 325 | 1.75 | .265 | .073 | .025 | .011 | ||
| 58 | 1.65 | .645 | .247 | .072 | .011 | 350 | 2.00 | .304 | .084 | .029 | .013 | ||
| 60 | 1.76 | .687 | .263 | .077 | .012 | 375 | 2.28 | .346 | .096 | .033 | .014 | ||
| 62 | 1.87 | .730 | .279 | .081 | .012 | 400 | 2.56 | 0.389 | 0.108 | 0.037 | 0.016 | ||
| 64 | 1.98 | .774 | .296 | .086 | .013 | 425 | 2.87 | .436 | .121 | .041 | .018 | ||
| 66 | 2.09 | .819 | .313 | .091 | .014 | 450 | 3.19 | .484 | .134 | .046 | .020 | ||
| 68 | 2.21 | .866 | .331 | .097 | .015 | 475 | .535 | .148 | .051 | .022 | |||
| 70 | 2.33 | .913 | 0.349 | 0.102 | 0.015 | 500 | .588 | .163 | .056 | .024 | |||
| 72 | 2.46 | 0.962 | .368 | .107 | .016 | 550 | .702 | .194 | .067 | .029 | |||
| 74 | 2.59 | 1.01 | .387 | .113 | .017 | 600 | .824 | .228 | .078 | .034 | |||
| 76 | 2.72 | 1.06 | .407 | .119 | .018 | 650 | 0.956 | .265 | .091 | .040 | |||
| 78 | 2.85 | 1.12 | .427 | .125 | .019 | 700 | 1.10 | .304 | .104 | .045 | |||
| 80 | 2.99 | 1.17 | .447 | .131 | .020 | 800 | 1.40 | .389 | .133 | .058 | |||
| 85 | 3.34 | 1.31 | .500 | .146 | .022 | 900 | 1.75 | .483 | .166 | .072 | |||
| 90 | 3.72 | 1.45 | .556 | .162 | .025 | 1000 | 2.12 | 0.587 | 0.201 | 0.088 | |||
| 95 | 4.11 | 1.61 | .615 | .179 | .027 | 1100 | .701 | .240 | .105 | ||||
| 100 | 4.52 | 1.77 | 0.676 | 0.197 | 0.030 | 1200 | .823 | .282 | .123 | ||||
| 105 | 4.94 | 1.93 | .740 | .216 | .033 | 1300 | 0.954 | .327 | .143 | ||||
| 110 | 5.39 | 2.11 | .806 | .235 | .036 | 1400 | 1.09 | .375 | .163 | ||||
| 115 | 5.85 | 2.29 | .875 | .255 | .039 | 1500 | 1.24 | .426 | .186 | ||||
| 120 | 6.33 | 2.48 | 0.947 | .276 | .042 | 2000 | 0.726 | .316 | |||||
| 125 | 2.67 | 1.02 | .298 | .045 | 2500 | 1.10 | .478 | ||||||
| 130 | 2.87 | 1.10 | .321 | .049 | 3000 | 0.669 | |||||||
| 135 | 3.08 | 1.18 | .344 | .052 | 3500 | 0.890 | |||||||
| 140 | 3.29 | 1.26 | .368 | .056 | 4000 | ||||||||
| 145 | 3.51 | 1.34 | .392 | .060 | 4500 | ||||||||
| 150 | 3.74 | 1.43 | 0.418 | 0.063 | 5000 | ||||||||
| (1) Not ASTM Standard pipe. | |||||||||||||
| POLY VINYL CHLORIDE (PVC) PLASTIC PIPE | |||||||||||||
| Pressure loss tables are provided for both SDR-PR and | |||||||||||||
| Schedule Wall PVC pipe. | |||||||||||||
| Unlike many pipes, the standard wall thickness of PVC | |||||||||||||
| pipe has a plus tolerance only, ranging from 0.020 in to | |||||||||||||
| 0.090 in. Many pressure loss tables use the standard | |||||||||||||
| minimum wall (without tolerances) for computation purposes. | |||||||||||||
| Since maufacturing processes preclude | |||||||||||||
| achievement of this thickness, most all PVC pipe will | |||||||||||||
| have a thicker wall and consequently a smaller ID. | |||||||||||||
| Accordingly, use of the standard wall to prepare loss | |||||||||||||
| tables is not realistic. The loss tables here use | |||||||||||||
| a wall thickness which includes one-half of the tolerances. | |||||||||||||
| This results in a more realistic average ID. This | |||||||||||||
| method of determining ID for calculation of pressure | |||||||||||||
| losses is recommended by the Plastic Pipe Institute (PPI). | |||||||||||||
| Caution should be exercised to control velocities in PVC | |||||||||||||
| pipe to avoid damage from pressure surging (water hammer). | |||||||||||||
| Note: PVC pressure loss tables can be used for any | |||||||||||||
| controlled OD thermoplastic pipe of the same SDR or | |||||||||||||
| Schedule number. | |||||||||||||